Send Message
Home > products > Automated Fundus Camera >
Digital Eye Fundus Camera 135° Wide Field Soft Lighting Intelligent Operation

Digital Eye Fundus Camera 135° Wide Field Soft Lighting Intelligent Operation

Digital Eye Fundus Camera

135° Wide Eye Fundus Camera

Soft Lighting Digital Eye Fundus Camera

Place of Origin:

China

Brand Name:

SYSEYE

Certification:

FDA

Model Number:

RetiCam 3100

Contact Us

Request A Quote
Product Details
Product Name:
Fundus Auto Fluorescence (FAF Optional) Automated Fundus Camera
Field Of View Tolerance:
±7%
Focus Adjustment Range:
±25D
Field View:
50°
Working Distance:
35mm
Minimum Pupil:
≥3.3mm
Focus Modes:
Manual/Auto
Rated Power Supply:
AC 100V~240V、50/60Hz
Payment & Shipping Terms
Minimum Order Quantity
1
Price
$12,000.00-$13,000.00
Delivery Time
5 working days
Payment Terms
, T/T
Supply Ability
100
Product Description

digital eye fundus camera 135° wide field soft lighting automatic intelligent operation

 

digital eye fundus camera RETICAM 3100 is based on the traditional fundus camera of our company, after years of research and development, through binocular stereo vision and XYZ 3D image feature recognition automatic positioning, and through the division line to achieve automatic focus. Through CCD imaging feedback, the exposure light is measured and the exposure intensity is determined automatically and correctly. Focusing step is controlled according to the image resolution, and image definition is adjusted to obtain clear and accurate fundus image.Automated Fundus Camera RetiCam 3100 has excellent optical imaging capability, easy to operate, less dependence on the operator, easier to obtain images.

digital eye fundus camera RETICAM 3100  Fundus auto fluorescence (FAF), as a new retinal imaging technology, has been widely used in clinical medicine since its advent. It has been demonstrated that FAF can be used to diagnose and monitor many fundus diseases, including posterior uveitis, quickly and noninvasively.

As a new application of non-invasive, non-contact, non-invasive, rapid and repeatable observation and monitoring of many fundus diseases including posterior uveitis, FAF has begun to play its unique role, and has attracted more and more attention of ophthalmologists and medical technicians.

 

 

Acquisition Modes Automated Fundus Camera/mydriatic Anterior photography /Red-free(optional)(FFA)/(FAF)
Field View 50°
Working Distance 35mm
Minimum Pupil ≥3.3mm
Focus Modes Manual/Auto
Alignment Modes Double dots auxiliary
Exposure Manual /Auto
Photography SLR Camera
Image definition 24 Megapixel
Compensation ±25D
Fixation External /Internal (any position available)
DICOM 3.0 Support

 

For patients who have an allergic reaction to strong light or who cannot receive light stimulation, please consult the physicians before imaging.

                                               Automated Fundus Camera in the world
Brand TOPCON(NW-400) DRS NEWVISON(RETICAM3100)
operation automatic(one key taking picutre)/manual automatic(one key taking picutre)/manual automatic(one key taking picutre)/manual
Acquisition modes fundus/anterior/? fundus/anterior/red-free filter fundus/anterior/red-free filter/FFA(optional)/FAF(optional)
Filed of view 45 degree 40-45degree 45-50degee
Mosic degee   80 degree 135degree
Minimum pipil size 3.3mm 3.5mm 3.3mm
Resolution above 18megapiexl sensor size:5 megapixel sensor resoultion: 48 pixel/degree above18 megapixel (24 megapixel optional )
Fixation 9 internal + 1 outside fixaiton 7 internal fixation countless fixaiton, any position is available during range + 1 outside fixation
Technology of focus     Dual camrea technology
exposure ligh standard standard new technology, more soft, one patient same eye can take picuture consecutive with almost same performace

 

Digital Eye Fundus Camera 135° Wide Field Soft Lighting Intelligent Operation 0

 

 

 

Company Introduction

Digital Eye Fundus Camera 135° Wide Field Soft Lighting Intelligent Operation 1

Focusing on the two major public health problems of adolescent myopia and elderly ophthalmology, our company researches new diagnostic and treatment equipment for ophthalmology, develops low-cost applicable technology products, realizes industrialization, reduces the cost of social medical and health system, and serves the strategic needs of national health.The company always adhere to the "high-tech,new vision" for the enterprise development concept.We have a strong technical force, has been awarded 11 patents, and obtained 13,485 quality system certification.Bio has established an efficient marketing team and a perfect after-sales service system to provide medical equipment with the highest cost performance and meticulous service.

Digital Eye Fundus Camera 135° Wide Field Soft Lighting Intelligent Operation 2

Send your inquiry directly to us

Privacy Policy China Good Quality Automated Perimetry Machine Supplier. Copyright © 2021-2024 perimetrymachine.com . All Rights Reserved.