Place of Origin:
China
Brand Name:
SYSEYE
Certification:
TUV
Model Number:
BIO-1100
Contact Us
automated perimetry machine Scientific and intelligent Simple one-stop modular software design
Eye disease can cause general or local loss of visual acuity in the visual field. The purpose of automated perimetry machine is to detect these defects early and follow up closely to help doctors treat them. Clinical visual field detection mainly measures the visual function of the inspected eye at specific points within the visual range, which can be used for the diagnosis of early glaucoma, long-term follow-up of glaucoma, neurofibropathy in various parts of the visual pathway, retinal diseases and neurological diseases, and provides a strong basis for the positioning and diagnosis of ocular diseases and intracranial diseases.
Specification | ||
Testing scope | 90° | |
Testing distance | 30CM | |
Background light | white31.5asb,yellow315asb | |
Visual target | 0.08asb---10000asb(0-51DB) | |
Target size | GoldmannⅠ, II ,III,IV,V | |
Visual target stimulation time | 200ms | |
Visual target interval time | Standard and custom | |
Threshold policy | Macula,10-2,24-2,30-2,60-4,nasal side | |
Upper threshold policy | C-40,C-64,C-76,FF-81,FF-120,FF-135…… | |
Special detection strategy | Esterman monocular,Esterman binocular,upper36°screening,blind point testing | |
Yellow-blue testing | Standard 440nm blue visual target + 315asb OG530yellow background brightness | |
Visual target | Red ,blue | |
Dynamic policy | Standard dynamic,blind dynamic,dark spot dynamic ,straight line dynamic | |
Custom policy | Static custom dynamic custom | |
Pupil size measurement | Auto | |
Fixation monitoring | Physiological blind spot monitoring,eye position monitoring,eye position moving alarm,eye tracking curve | |
Environment light testing | Auto | |
Analysis software | reliability analysis , single report, triple report, GHT glaucoma semi vision report, GPA glaucoma developing analysis, VFI analysis, Blue-yellow analysis | |
System | Win7 above | |
Others | ||
Size | 412mm(length)* 497mm(width)* 513mm(height) | |
Wight | 17kg | |
Power |
100-240V HZ:50-60Hz |
Technical Features:
* Rigorous implementation of Goldman international standard.
* Halogen projection system:Stimulation light source is from wide band visible spectrum, fully meet colored cone cell stimulation.
* Accurate and elaborate database of normal population of all age groups, recognition of more subtle early visual field defects.
* GHT glaucoma semi vision analysis, make glaucoma diagnosis easier.
* GPA glaucoma progression analysis upgrade, slight glaucoma development is obvious.
* Standard SWAP blue-yellow visual field examination, sensitive to earlier visual field defects. * Scientific and intelligent interactive inspection strategy, 30° range visual field inspection only takes 3 minutes.
* Simple one-stop modular software design, equipment operation learning only 2 minutes.
Company Introduction
Focusing on the two major public health problems of adolescent myopia and elderly ophthalmology, our company researches new diagnostic and treatment equipment for ophthalmology, develops low-cost applicable technology products, realizes industrialization, reduces the cost of social medical and health system, and serves the strategic needs of national health.The company always adhere to the "high-tech,new vision" for the enterprise development concept.We have a strong technical force, has been awarded 11 patents, and obtained 13,485 quality system certification.Bio has established an efficient marketing team and a perfect after-sales service system to provide medical equipment with the highest cost performance and meticulous service.
Send your inquiry directly to us