non-contact tonometer no risk of infection, simple operation and easy acceptance by patients
Auto tonometer utilizes image control and feature recognition for auto 3-D positioning of xyz with reliable judgment and measurement results, and easy to operate. The air non-contact approach to measure IOP can also be used for corneal thickness (ST-1000P).The normal value of human intraocular pressure is 10~20mmHg. The intraocular pressure beyond this range may be caused by a variety of reasons, such as excessive eye use, visual fatigue, long-term desk work, the use of computers or mobile phones for more than 4 hours a day. In addition, it may also be due to some diseases, such as: Glaucoma, diabetes, cardiovascular disease, siriasis, cataract, myopia, trauma, etc. But because each person optic nerve is different to the tolerance of intraocular pressure, although some intraocular pressure is higher than the normal value, the damage of optic nerve and visual field does not occur. Non Contact Tonometer is one of the most effective ways to check for intraocular pressure
Product Description Of Non Contact Tonometer
Screen color and touch,
Rotating screen like Topcon.
Motorized chinrest
Auto tracking eye , you can select auto or manual .
if select auto , will automatic adjust the chinrest distance , height, and shoot air to measure . two second finish .
Intraocular pressure (IOP) measuring range: 1mmHg~ 30mmHg /1mmHg ~60mmHg ( precision of 1mmHg)
Measuring system: dual sensor system of light and pressure
Working distance:≥11mm
R/L: automatic detection and display
Measuring result: 10 times per eye; 3 times result printing per eye
Recording: build-in printer
Measuring mode: auto/manual
Focus: when luminous spot is in the focus frame, 2 modes can be chosen.
Auto mode: auto intraocular pressure measurement
Manual mode: when it's good focus, the frame will turn yellow into green, and click to start the measurement
Error indication: if the measurement signal is weak, the IOP will be enclosed by ( ), or display “ERR ”
Safety limit button: install measurement for minimum distance between head and patient
Safety functions: the distance between air nozzle and cornea is controlled in preset range(such as 11mm); it will stop going forward when the cornea is too closed to air head.
Movement range:≥30mm(front to back)/ 90mm(left to right)/ 30mm(vertical)
Jaw layer vertical movement: 0~65mm with under jaw layer
Display mode: 10.1-inch HDMI color LED touch monitor
Output port: USB2.0
Working platform: electric elevating platform
Non Contact Tonometer specification
Intraocular pressure (IOP) measuring range | 1mmHg~ 30mmHg /1mmHg ~60mmHg ( precision of 1mmHg) |
Measuring system | dual sensor system of light and pressure |
Working distance | ≥11mm |
R/L | automatic detection and display |
Measuring result | 10 times per eye; 3 times result printing per eye |
Recording | build-in printer |
Measuring mode | auto/manual |
Movement range | ≥30mm(front to back)/ 90mm(left to right)/ 30mm(vertical) |
Jaw layer vertical movement | ≥30mm(front to back)/ 90mm(left to right)/ 30mm(vertical) |
Display mode | 10.1-inch HDMI color LED touch monitor |
Output port | USB2.0 |
Company Introduction
Focusing on the two major public health problems of adolescent myopia and elderly ophthalmology, our company researches new diagnostic and treatment equipment for ophthalmology, develops low-cost applicable technology products, realizes industrialization, reduces the cost of social medical and health system, and serves the strategic needs of national health.The company always adhere to the "high-tech,new vision" for the enterprise development concept.We have a strong technical force, has been awarded 11 patents, and obtained 13,485 quality system certification.Bio has established an efficient marketing team and a perfect after-sales service system to provide medical equipment with the highest cost performance and meticulous service.