digital fundus camera fundus photography equipment FFA FAF Red-free
Digital Fundus Camera RetiCam 3100 can be used to capture the anterior and posterior eye images. It has a field of view of 50 degrees for fundus imaging.Digital Fundus Camera Reticam 3100 is a highly recognized and popular automatic fundus imaging system around the world. Through dual camera imaging, image control and feature recognition, eye XYZ 3D automatic positioning is realized. Through CCD imaging feedback, the exposure is measured, and the exposure intensity is automatically and accurately determined, without the need for a doctor's complex operation. By controlling the focusing step length according to the image resolution, the image definition can be automatically adjusted to obtain a clear and accurate fundus image and help doctors make accurate judgments for patients.
Field of view | 50° |
Field of view tolerance | ±7% |
Resolution | |
Center of view | ≥60 lp/mm |
Field of view center (r/2) | ≥40 lp/mm |
At the edge of the field of view (r) | ≥25 lp/mm |
Magnification | 1.3 times |
Required pupil diameter | 4.0 mm or more (3.3 mm or more when using the small pupil shooting function) |
Working distance | 35 mm |
Focus adjustment range | ±25D |
Shooting light | Auto: with shooting mode |
Manual: can be set manually | |
light source | |
Illumination light | Infrared led |
Shooting light | Xenon lights |
reflected light | |
Scattered light | |
camera | Digital camera |
Fixing light | Internal fixing light (LED) |
External fixation light | |
Moving range | |
Stage | 90 mm left and right, 35 mm front and rear |
Main unit moves vertically | 30 mm |
Chin-rest tray movement range | 60 mm |
Rated power supply | AC 100V~240V,50/60Hz |
size | 380 mm(L)x 550 mm(W)x 475 mm(H) |
weight | About 26.5kg |
When in maximum light intensity/hole bar state | |
Spectral wavelength | 305 nm~1100 nm |
The design of the RetiCam 3100 complies with the EMC standard IEC 60601-1-2 (EN 60601-1-2) for medical electrical equipment. The installation and use of the device must comply with the following EMC statement.
Turning off/on the power of this unit may cause interference to other equipment.In this case, please try the following measures.
If the above measures still do not solve the problem, please stop using the device and consult with the company's after-sales personnel.
Company Introduction
Focusing on the two major public health problems of adolescent myopia and elderly ophthalmology, our company researches new diagnostic and treatment equipment for ophthalmology, develops low-cost applicable technology products, realizes industrialization, reduces the cost of social medical and health system, and serves the strategic needs of national health.The company always adhere to the "high-tech,new vision" for the enterprise development concept.We have a strong technical force, has been awarded 11 patents, and obtained 13,485 quality system certification.Bio has established an efficient marketing team and a perfect after-sales service system to provide medical equipment with the highest cost performance and meticulous service.