The Visual Field Analyzer (BIO-1100) instrument belongs to the category of medical examination equipment. It is an important means to determine the development of glaucoma, optic chiasm damage, neurological disease, toxic amblyopia, retinal disease, choroidal disease and other diseases by alignment the change of visual field. This product For scientific research, teaching, and clinical use. Projection Perimeter is suitable for auxiliary diagnosis of glaucoma. Purpose of visual field examination
Technical Specification of Projection Perimeter
Specification | ||
Testing scope | 90° | |
Testing distance | 30CM | |
Background light | white31.5asb,yellow315asb | |
Visual target | 0.08asb---10000asb(0-51DB) | |
Target size | GoldmannⅠ, II ,III,IV,V | |
Visual target stimulation time | 200ms | |
Visual target interval time | Standard and custom | |
Threshold policy | Macula,10-2,24-2,30-2,60-4,nasal side | |
Upper threshold policy | C-40,C-64,C-76,FF-81,FF-120,FF-135…… | |
Special detection strategy | Esterman monocular,Esterman binocular,upper36°screening,blind point testing | |
Yellow-blue testing | Standard 440nm blue visual target + 315asb OG530yellow background brightness | |
Visual target | Red ,blue | |
Dynamic policy | Standard dynamic,blind dynamic,dark spot dynamic ,straight line dynamic | |
Custom policy | Static custom dynamic custom | |
Pupil size measurement | Auto | |
Fixation monitoring | Physiological blind spot monitoring,eye position monitoring,eye position moving alarm,eye tracking curve | |
Environment light testing | Auto | |
Analysis software | reliability analysis , single report, triple report, GHT glaucoma semi vision report, GPA glaucoma developing analysis, VFI analysis, Blue-yellow analysis | |
System | Win7 above | |
Others | ||
Size | 412mm(length)* 497mm(width)* 513mm(height) | |
Wight | 17kg | |
Power |
100-240V HZ:50-60Hz |
Feature of Projection Perimeter
* Rigorous implementation of Goldman international standard.
* Halogen projection system:Stimulation light source is from wide band visible spectrum, fully meet colored cone cell stimulation.
* Accurate and elaborate database of normal population of all age groups, recognition of more subtle early visual field defects.
* GHT glaucoma semi vision analysis, make glaucoma diagnosis easier.
* GPA glaucoma progression analysis upgrade, slight glaucoma development is obvious.
* Standard SWAP blue-yellow visual field examination, sensitive to earlier visual field defects
* Scientific and intelligent interactive inspectio strategy, 30° range visual field inspection only takes 3 minutes.
* Projection Perimeter Simple one-stop modular software design, equipment operation learning only 2 minutes
* Zeiss humphrey 860 same function
This product is warranted for one year from the date of purchase.
Company Introduction
Focusing on the two major public health problems of adolescent myopia and elderly ophthalmology, our company researches new diagnostic and treatment equipment for ophthalmology, develops low-cost applicable technology products, realizes industrialization, reduces the cost of social medical and health system, and serves the strategic needs of national health.The company always adhere to the "high-tech,new vision" for the enterprise development concept.We have a strong technical force, has been awarded 11 patents, and obtained 13,485 quality system certification.Bio has established an efficient marketing team and a perfect after-sales service system to provide medical equipment with the highest cost performance and meticulous service.